<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-22 04-05-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 69 kHz 12230 12,7146
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,33 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 69 kHz MIN: 12 kHz % above 76 kHz: 12,7146 Acquired: 2025/05/22 4.04.23 Total samples: 12230 Equivalent time: 0:10:11 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,2 dBr MIN: 4,7 dBr AVE: 5,33 dBr % above 12,2 dBr: 0,0 Last value: 6,1 dBr (2025/05/22 4.04.22) 03.50 03.52 03.54 03.56 03.58 04.00 04.02 04.04 0 2 4 6 Pm [dBr]